Документы
Документы не прикреплены. Запросите технический лист выбранного исполнения.
Оригиналы документов: язык и обозначения сохранены.
Карточка характеристик
Примечания к источникам
Оригинальные примечания на английском языке.
Official Kubota generator-engine category and exact model parameter tables reviewed 2026-11-06.
Base model record, distinct from region/customer-specific suffix records; specifications must not be transferred automatically to those variants.
Source engine.kubota.com · источник.
Engine Model: D722-E2; Emission Regulation: EPA/CARB Tier 2 level; Type: Vertical, water cooled 4-cycle diesel engine; Cylinders: 3; Bore and Stroke
mm(in): 67.0 x 68.0 (2.64 x 2.68); Displacement
L (cu.in): 0.719 (43.88); Aspiration: Naturally aspirated; Aftertreatment: -; Stand-by output / speed *1 kW (HP) / rpm: 13.3 (17.8) / 3600; Continuous output / speed *2 kW (HP) / rpm: 12.2 (16.4) / 3600; Combustion System: Indirect injection; Fuel System: In-line pump; Length x Width x Height *3 (Without Aftertreatment Unit) mm (in): 485 x 386 x 564 (19.1 x 15.2 x 22.2); Length x Width x Height *4 (With Aftertreatment Unit) mm (in): -; Dry Weight kg (lb): 88 (194).
Source engine.kubota.com · источник.
Engine Model: D722-E2; Emission Regulation: EPA/CARB Tier 2 level; Type: Vertical, water cooled 4-cycle diesel engine; Cylinders: 3; Bore and Stroke
mm(in): 67.0 x 68.0 (2.64 x 2.68); Displacement
L (cu.in): 0.719 (43.88); Aspiration: Naturally aspirated; Aftertreatment: -; Stand-by output / speed *1 kW (HP) / rpm: 11.3 (15.1) / 3000; Continuous output / speed *2 kW (HP) / rpm: 10.3 (13.8) / 3000; Combustion System: Indirect injection; Fuel System: In-line pump; Length x Width x Height *3 (Without Aftertreatment Unit) mm (in): 485 x 386 x 564 (19.1 x 15.2 x 22.2); Length x Width x Height *4 (With Aftertreatment Unit) mm (in): -; Dry Weight kg (lb): 88 (194).
Outputs are manufacturer SAE J1349 net mechanical continuous and stand-by ratings, not electrical kWe.
Continuous is not relabelled ISO prime.
Multiple speed ratings and any differing specifications remain in these source-qualified notes; nonunique scalar fields are withheld.
Dimensions exclude cooling fan and aftertreatment unit as stated by source.
Production status not confirmed; discontinued is the user-authorized catalogue classification for unknown status, not manufacturer-confirmed withdrawal.
FLAG: nonunique table fields: Continuous output.